GS w
Function:
Set bar code width
Code:
ASCII
GS
w
n
Hex
1D
77
n
Decimal
29
119
n
Range:
2 ≤ n ≤ 6
Default:
n=3
Description:
This command sets the horizontal size of the bar code, using n as follows:
n
Multi-level bar code module
width (mm)
Binary-level bar code
Thin element width (mm)
Thick element width (mm)
2
0.250
0.250
0.625
3
0.375
0.375
1.000
4
0.500
0.500
1.250
5
0.625
0.625
1.625
6
0.750
0.750
2.000
n specifies the bar code module width.
Remarks:
The setting of this command is effective for the following bar codes:
Multi-level bar codes (UPC-A, UPC-E, JAN13, HAN8, CODE93, CODE128)
Binary-level bar codes (CODE39, ITF, CODABAR)
The setting of this command remains effective until ESC @, printer reset or power cycling is executed.