SPP-R210 Command Manual
Rev. 1.00 BIXOLON
<Function 069> GS ( k pL pH cn fn m n (fn=69)
(pL + pH x 256) = 4 (pL=4, pH=0)
cn=48
fn=69
m=48
48 ≤ n ≤ 56
0≤n≤8
■ This command specifies the error correction level for PDF417.
• The error correction level is set by “level”
■ Settings of this function affect the processing of Functions 081.
■ Error correction level specified by “level” (m=48) is as follows:
The number of the error correction codeword is unchanged regardless of the number of codeword in the data area.
Number of error correction codeword
■ The setting of this command remains effective until ESC @, printer reset or power cycling is executed.