- 119 -
<Function 48> BS ^ P fn (fn=0,48)
Code :
ASCII
BS
^
P
fn
m
t
Hex
08
5E
50
fn
m
t
Decimal
08
94
84
fn
m
t
Range:
fn=0,48, 0 ≤ m ≤ 1
5 ≤ t ≤ 255
Default:
m = 1, t = 20
Description :
Set the power saving mode and time to change the sataus of printer.
Remarks :
The m=0 : power saving mode disable.
The m=1 : power saving mode enable.
The power saving set time is [t x 1s] and the default time is 20 sec.
If n is smaller than 5 the power saving time is set to defaut [20 x 1s].