BIXOLON SRP-352plusIII Manual de usuario Pagina 37

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 120
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 36
SRP-350/352plusIII
Rev. 1.00 BIXOLON
- 37 -
ESC S
Function:
Select standard mode
Code:
ASCII
ESC
S
Hex
1B
53
Decimal
27
83
Range:
None
Default:
None
Description:
This command enables standard mode.
Remarks:
The data in the printer buffer is cleared and the setting by ESC W returns to the default.
The conditions by the following commands are defined independently in standard mode and page mode.
ESC SP, ESC 2, and ESC 3
In standard mode, CAN and GS $ are ignored.
Differences:
None
Vista de pagina 36