SRP-350/352plusIII
Rev. 1.00 BIXOLON
- 47 -
ESC p
Function:
Generate pulse
Code:
ASCII
ESC
p
m
t1
t2
Hex
1B
70
m
t1
t2
Decimal
27
112
m
t1
t2
Range:
m = 0, 1, 48, 49
0 ≤ t1 ≤ 255, 0 ≤ t2 ≤ 255
Default:
None
Description:
This command outputs the signals specified with t1 and t2 to the connector pins defined by m.
m
Connector pin
0, 48
Drawer kick-out connector pin 2
1, 49
Drawer kick-out connector pin 5
Remarks:
The ON time is [t1 x 2ms], and the OFF time is as [t2 x 2ms].
If t2 is smaller than t1, OFF time is set to [t1 x 2ms].
Differences: