<Function 64> GS ( L pL pH m fn d1 d2 (fn=64)
[Format]
[Range]
[Description]
ASCII GS ( L pL pH m fn d1 d2
Hex 1D 28 4C pL pH m fn d1 d2
Decimal 29 40 76 pL pH m fn d1 d2
(pL + pH x 256) = 4 (pL=4, pH=0)
m=48
fn=64
d1=75, d2=67
Transmits the defined NV graphics key code list.
- When the key code is present :
Hexadecimal Decimal Amount of Data
Header 37H 55 1 byte
Flag 72H 114 1 byte
Status 40H or 41H 64 or 65 1 byte
Data 30H - 39H 48 - 57 2 - 80 bytes
NUL 00H 0 1 byte
- When the key code is not present :
Hexadecimal Decimal Amount of Data
Header 37H 55 1 byte
Flag 72H 114 1 byte
Status 40H 64 1 byte
NUL 00H 0 1 byte
If the number of the key code exceed 40, the key code is transmitted
dividing up to 40.
- The status if the continuous transmission data block is present is 41H.
- The status if the continuous transmission data block is not present is
40H.
After the [Header-NULL] is transmitted, the printer receives a response
from the host; then it performs the process defined by the response. (See
the tables below.)
- When the status (existence of the next data block) is Hexadecimal =
41H / Decimal = 65
Response
ASCII Decimal
Process performed
ACK 6 Transmits the next data.
NAK 21 Transmits the previous data again.
CAN 24 Ends the process.
- When the status (for the last data block) is Hexadecimal = 40H /
Decimal = 64
Response
ASCII Decimal
Process performed
ACK 6 Ends the process.
NAK 21 Transmits the previous data again.
CAN 24 Cancels the process.