Rev. 1.03
- 37 -
SRP-350/352plusA&C
<Function 066> GS ( k pL pH cn fn n (fn=66)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 42 n
Decimal 29 40 107 3 0 48 66 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=66
n=0, 3 ≤ n ≤ 90
n=0
Specifies the number of rows of the data area of PDF417.
- n=0 specifies auto processing
- When n is not 0, specifies the number of rows of the symbol as n rows.
▪ Settings of this function affect the processing of Functions 081 and 082.
▪
When auto processing (n=0) is specified, the maximum number of rows is 90.
▪ When auto processing (n=0) is specified, the number of rows is calculated
by the printing area when processing Functions 081, 082, module height
(Function 068).
▪ Setting of this function are effective until ESC @ is executed, the printer is
reset, or the power is turned off.
<Function 067> GS ( k pL pH cn fn n (fn=67)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 43 n
Decimal 29 40 107 3 0 48 67 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=67
1 ≤ n ≤ 4
n=3
Specifies the width of a module of PDF417 symbol.
▪ Settings of this function affect the processing of Functions 081 and 082.
▪ The setting unit differs, depending on the printer models.
▪ Setting of this function are effective until ESC @ is executed, the printer is
reset, or the power is turned off.
<Function 068> GS ( k pL pH cn fn n (fn=68)
[Format]
[Range]
[Default]
[Description]
[Notes]
ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 30 44 n
Decimal 29 40 107 3 0 48 68 n
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=68
2 ≤ n ≤ 8
n=3
Specifies the module height of PDF417 symbol.
- Specify the height to [a module width x n].
▪ Settings of this function affect the processing of Functions 081 and 082.
▪ Setting of this function are effective until ESC @ is executed, the printer is
reset, or the power is turned off.