Rev. 1.03
- 9 -
SRP-350/352plusA&C
[Notes] - Executes the printer power off.
If this command is encountered, the printer will not continue to process
anything. To recover the printer to print again, it is necessary to turn the
power on again or execute a hardware reset.
If print data includes a character string with this command, the printer
performs the command. User must consider this.
- For example : Bit image data accidentally might include a data string
with this command.
Do not embed this command within another command.
- For example : Bit image data might include this command.
This command is ignored block data is transmitted.
DLE DC4 fn d1...d7 (fn=8)
[Name]
[Format]
[Range]
[Description]
Clear buffer(s).
ASCII DLE DC4 fn d1...d7
Hex 10 14 8 d1...d7
Decimal 16 20 8 d1...d7
fn=8
d1=1, d2=3, d3=20, d4=1, d5=6, d6=2, d7=8
Clear all data stored in the receive buffer and the print buffer.
Transmits the following three bytes data.
Hex Decimal Amount of data
Header 37 H 55 1 byte
Flag 25 H 37 1 byte
NUL 00 H 0 1 byte
[Notes] Enters standard mode.
The command must be inhibited for use in a system using this printer and
the EPSON OPOS.
If print data includes a character string with this command, the printer
performs the command. User must consider this.
- For example : Bit image data accidentally might include a data string
with this command.
Do not embed this command within another command.
- For example : Bit image data might include this command.
This command is ignored block data is transmitted.
ESC FF
[Name]
[Format]
[Description]
Print data in page mode.
ASCII ESC FF
Hex 1B 0C
Decimal 27 12
In page mode, prints all buffered data in the printing area collectively.