<Function 50> BS ^ L pL pH fn (fn=2, 50)
Code:
ASCII
GS ( L pL pH m fn
Hex
1D 28 4C pL pH m fn
Decimal
29 40 76 pL pH m fn
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
m=48, fn=2, 50
Default:
None
Description:
This command prints the graphics data defined by the process of Function 112.
Remarks:
The graphics data stored in the printer buffer is printed.
This command is available in standard mode, not in page mode.
The graphics data is defined by Function 112.
The required amount of line feed pitch is used for printing graphics data, regardless of the existing setting value of the
pitch.
Differences:
This command is available in both standard and page modes.