SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 81 -
<Function 281> GS ( k pL pH cn fn m (fn=81)
Code:
ASCII
GS ( k pL pH cn fn m
Hex
1D 28 6B 03 00 32 51 m
Decimal
29 40 107 3 0 50 81 m
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=50
fn=81
m=48
Default:
None
Description:
This command encodes and prints Maxi Code symbol data saved in the storage area.
Remarks:
■ In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is
empty.
■ A symbol exceeding the printing area in size can not be printed.
■ Printing operation is not processed under the following conditions:
• There is no data. (Function 280 is not executed)
• The number of numeric characters exceeds 138
• The number of alphanumeric characters exceeds 93
• When mode 2 is selected, the primary message does not include all of the following:
Primary Message Data Number Character
Postal code 1~9 Numeric
ISO country code 1~3 Numeric
Service type code 1~3 Numeric
• When mode 3 is selected, the primary message does not include all of the following:
Primary Message Data Number Character
Postal code 1~6 Setting Code A
ISO country code 1~3 Numeric
Service type code 1~3 Numeric