<Function 2> GS ( E pL pH fn d1 d2 d3 (fn=2)
Code:
ASCII
GS ( E pL pH fn d1 d2 d3
Hex
1D 28 45 pL pH fn d1 d2 d3
Decimal
29 40 69 pL pH fn d1 d2 d3
Range:
(pL + pH x 256) = 4 (pL=4, pH=0)
fn=2
d1=79, d2=85, d3=84
Default:
None
Description:
This command terminates the user setting mode and performs a software reset.
Remarks:
■ This command activates setting items set in the user setting mode.
■ All the setting items will be effective only after performing this command.
■ After executing a software reset, the printer resumes the setting in effect at power on.
Differences:
None