SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 127 -
Third byte (paper sensor information)
Bit Off/On Hex Decimal Function
0,1 Off 00 0 Not used. Fixed to Off
Off 00 0 Paper end sensor: paper present
2,3
On 0C 12 Paper end sensor: no paper present
4 Off 00 0 Not used. Fixed to Off
5 Off 00 0 Not used. Fixed to Off
6 Off 00 0 Not used. Fixed to Off
7 Off 00 0 Not used. Fixed to Off
Fourth byte (paper sensor information)
Bit Off/On Hex Decimal Function
0 On 01 1 Not used. Fixed to On
1 On 02 2 Not used. Fixed to On
2 On 04 4 Not used. Fixed to On
3 On 08 8 Not used. Fixed to On
4 Off 00 0 Not used. Fixed to Off
5 Off 00 0 Not used. Fixed to Off
6 Off 00 0 Not used. Fixed to Off
7 Off 00 0 Not used. Fixed to Off