BIXOLON SPP-R300 Especificaciones Pagina 107

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 149
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 106
SPP-R300 Command Manual
Rev. 1.00 BIXOLON
- 107 -
<Function 64> GS ( L pL pH m fn d1 d2 (fn=64)
Code:
ASCII
GS ( L pL pH m fn d1 d2
Hex
1D 28 4C pL pH m fn d1 d2
Decimal
29 40 76 pL pH m fn d1 d2
Range:
(pL + pH x 256) = 4 (pL=4, pH=0)
m=48
fn=64
d1=75, d2=67
Default:
None
Description:
Transmits the defined NV graphics key code list.
- When the key code is present :
Hexadecimal Decimal Amount of Data
Header 37H 55 1 byte
Flag 72H 114 1 byte
Status 40H or 41H 64 or 65 1 byte
Data 30H - 39H 48 - 57 2 - 80 bytes
NUL 00H 0 1 byte
- When the key code is not present :
Hexadecimal Decimal Amount of Data
Header 37H 55 1 byte
Flag 72H 114 1 byte
Status 40H 64 1 byte
NUL 00H 0 1 byte
If the number of the key code exceeds 40, the key code is transmitted dividing up to 40.
- The status if the continuous transmission data block is present is 41H.
- The status if the continuous transmission data block is not present
is 40H.