SRP-F310/312
Rev. 1.00 BIXOLON
- 12 -
DLE EOT
Function: Transmit real-time status
Code:
ASCII
DLE EOT n
Hex
10 04 n
Decimal
16 4 n
Range:
1 ≤ n ≤ 4
Default:
None
Description:
This command enables commands to be operable in real-time.
This command transmits the printer-related status specified by n as follows:
n Function
1 Transmit printer status
2 Transmit off-line status
3 Transmit error status
4 Transmit paper roll sensor status
■
Printer transmits the following status
n=1: Printer status
Bit Binary Hex Decimal Status
0 0 00 0 Not used. Fixed to Off
1 1 02 2 Not used. Fixed to On
0 00 0 Drawer kick-out connector pin 3 is LOW
2
1 04 4 Drawer kick-out connector pin 3 is HIGH
0 00 0 Online
3
1 08 8 Offline
4 1 10 16 Not used. Fixed to On
5 0 00 0 Not used. Fixed to Off
Comentarios a estos manuales