SRP-F310/312
Rev. 1.00 BIXOLON
- 27 -
ESC 3
Function: Set line spacing
Code:
ASCII
ESC 3 n
Hex
1B 33 n
Decimal
27 51 n
Range:
0 ≤ n ≤ 255
Default:
Corresponding to the default line spacing defined by ESC 2
Description:
■ This command sets the line spacing using a following rule.
• Line spacing = n x (vertical or horizontal motion units)
Remarks:
■ With standard mode selected, the vertical motion unit is used.
■ In page mode, the horizontal motion unit is applied when printing start poison is defined to the upper right or lower
right of print area using ESC T, otherwise, the vertical motion unit is used.
■ The line spacing is settable independently for each of standard and page modes.
Differences:
Vertical or horizontal motion unit and maximum line spacing settable:
Model Vertical unit Horizontal unit Max line spacing
SRP-F310 0.0705mm (1/360 inch) 0.141mm (1/180 inch) 17.98mm
SRP-F312 0.0625mm (1/406 inches) 0.125mm (1/203 inches) 15.937mm