GS f
Function: Select font for HRI characters
Code:
ASCII
GS f n
Hex
1D 66 n
Decimal
29 102 n
Range:
n = 0, 1, 48, 49
Default:
n = 0
Description:
This command selects a font for the HRI(Human Readable Interpretation) characters used when printing a bar code,
using n as follows:
n Font
0, 48 Font A
1, 49 Font B
Remarks:
The setting of this command is applied to only HRI characters.
The printing position of HRI characters are specified by GS H.
The configurations of Font A and B vary depending on the printer model.