SRP-F310/312
Rev. 1.00 BIXOLON
- 96 -
<Function 081> GS ( k pL pH cn fn m (fn=81)
Code:
ASCII
GS ( k pL pH cn fn m
Hex
1D 28 6B 03 00 30 51 m
Decimal
29 40 107 3 0 48 81 m
Range:
(pL + pH x 256) = 3 (pL=3, pH=0)
cn=48
fn=81
m=48
Default:
None
Description:
This command encodes and prints the PDF417 symbol data in the symbol save area.
Remarks:
In standard mode, this command is available only when printer is at the beginning of a line or the printer buffer is
empty.
A symbol exceeding the printing area in size can not be printed.
Printing operation is not processed under the following conditions:
There is no data (Function 080 is not processed).
If [(number of columns x number of rows) < number of code word] when automatic processing is specified for
number of columns and number of rows.
Number of code word exceeds 928 in the data area.
The following data is added automatically by the encode processing:
Start pattern and stop pattern.
Indicator code word of left and right.
The descriptor of symbol length (the first code word in the data area).
The error correction code word calculated by modulus 929.
Pad codeword.
The data area includes the following codewords:
Data specified by Function 080.
The descriptor of symbol length (the first code word in the data area).