Vista de pagina 25
SRP-F310/312
Rev. 1.00 BIXOLON
- 26 -
ESC 2
Function: Select default line spacing
Code:
ASCII
ESC 2
Hex
1B 32
Decimal
27 50
Range:
None
Default:
None
Description:
This command sets the default line spacing The default line spacing is approximately 3.75 mm, which is equivalent to
30 dots.
Remarks:
The line spacing can be set independently in standard mode and in page mode.
The setting of this command remains effective until ESC !, ESC @, printer reset or power cycling is executed.
Differences:
Default line spacing:
SRP-F310: 4.23 mm (30 dots)
SRP-F312: 3.75 mm(30 dots)