BIXOLON SRP-F312 Especificaciones Pagina 60

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 145
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 59
SRP-F310/312
Rev. 1.00 BIXOLON
- 60 -
GS ( A
Function: Execute test print
Code:
ASCII
GS ( A pL pH n m
Hex
1D 28 41 pL pH n m
Decimal
29 40 65 pL pH n m
Range:
(pL + pH x 256) = 2 (pL=2, pH=0)
0 n 2, 48 n 50
1 m 2, 49 m 50
Default:
None
Description:
This command prints a specified pattern for testing on a roll paper.
Roll paper is selected with n specified as follows:
n Paper type
0, 48
1, 49
2, 50
Roll paper
Different kinds of test patterns are selected according to m as follows:
m Test pattern
1, 49 Hexadecimal dump mode
2, 50 Self-test printing(configuration+default codepage)
3, 51 Not operated
Remarks:
The printer cancels a macro definition in progress If this command is processed. The macro becomes invalid.
After completion of this command, a software reset is executed automatically to restore the printer status set during
power cycling.
All of the data transmitted from the host to the printer is printed and identified in hexadecimal dump mode.
The real time command and LSB operations are not executed during the printing of printer configuration (m=2, 50).
Differences:
None