BIXOLON SRP-F312 Especificaciones Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 145
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
SRP-F310/312
Rev. 1.00 BIXOLON
- 59 -
GS $
Function: Set absolute vertical print position in page mode
Code:
ASCII
GS $ nL nH
Hex
1D 24 nL nH
Decimal
29 36 nL nH
Range:
0 (nL + nH x 256) 65535 (0 nL 255, 0 nH 255)
Default:
None
Description:
This command sets the absolute vertical print starting position to [(nL + nH × 256) × (vertical or horizontal motion unit)].
Remarks:
This command is activated only in page mode and ignored in standard mode.
Either vertical or horizontal motion unit is used according to the print direction set by ESC T as follows:
With the starting position of the upper left or lower right on the print area, the vertical motion unit is used.
In other cases, the horizontal motion unit is used.
The configuration beyond the print area set by ESC W is ignored.
Differences:
None